  • Insert black O-ring in the retainer, place the retainer on the ball head exposed in the mouth and take an impression.
  • Connect lab analog to the retainer in the impression.
  • After manufacturing the working model, remove the retainer from the impression according to the general rules.
  • Using the completed working model, manufacture denture according to the general rules.
  • Check the insertion points of the denture.
  • Push the O-ring through the rubber dam. Insert the yellow O-ring into the retainer. Attach the retainer to the O-ring abutment.
  • Inject resin into the hole formed on denture and remove the surplus after resin has hardened.
  • Check the bearing and occlusion status.
  • Considering path, insert HM implant according to the set surgery procedure.
  • After checking the location of insertion, form the hole on the existing denture.
  • Connect rubber dam and then connect ball head by inserting O-Ring with weak bearing into the retainer.
  • Inject resin after setting the existing denture formed hole. Remove the surplus part after resin has hardened.
  • Check the retention force and occlusion status.